Free C-20: HVAC practice test

  • 15 questions
  • ~8 minutes
  • Scored instantly

15 questions from the Peerless Institute C-20: HVAC exam, including five questions about one diagram. The C-20: HVAC exam covers the following topics:

  • Planning and Estimating22%
  • Fabrication, Installation, and Startup38%
  • Troubleshooting, Repair, and Maintenance20%
  • Safety20%

Percentages are approximate, per the CSLB examination content outline.

Study materials for this exam

0 of 15 answered
  1. 1Mr. Able is working on a 8' x 2.5' metal rolling scaffold that is six feet high. It has 6" rubber wheels and the floor has a 2 degree pitch. Mr. Able is finished at this location and needs to move to a different area. Mr. Able instructs his partner to move the scaffold to a different location while he is still on it. He has proceeded:(NOTE: In order to ride on staging, the floor surface must be within 3 degrees of level. When riding on staging, the minimum dimension of the base is at least 1/2 of the height.)

  2. 2How close to the ground can a metal duct be installed? (Ducts beneath concrete slab must be encased in at least 2 inches of concrete. )

  3. 3How many cfm are required if the heat loss of a room is 8,500 Btu, the register is 20 feet from the furnace, the temperature is 150 degrees bonnet and the design factor is 12.5?

  4. 4A duct has a design static pressure drop of .08" WC. The duct section is 160 feet long and the static pressure drop of the duct section is: (See Page 36 of the Test Booklet.)

  5. 5A grill in a distribution system must handle 1500 cfm of air at a face velocity of 500 fpm. The height of the duct must be 18 inches and the width of the grill is A. 28.4 inches.

  6. 6What is incorrect about the following statement? Duct material is to be made of zinc-coated sheets which will be not less than .5 ounce per square foot on both sides of a sheet. The coating will withstand flaking through bending of 180 degrees in any direction at room temperature.

  7. 7When pneumatic nailers and staplers are in use, all personnel, except tool operators, may not come within how many feet of the area?

  8. 8The volume of a room per 1000 Btu/h of aggregate input ratings for appliances must be a minimum of ______ cu. ft., according to the mechanical code.

  9. 9Metal ladders should be at least ___ feet from 220 volt electrical wiring.

  10. 10An office with dimensions 20' x 25' x 8' needs at least 4 air changes per hr. In order to have comfort standards, how many CFMs are necessary?

Diagram practice

Use this diagram to answer the next five questions. Use the stated exercise data; the drawing is not to scale.

Four-component cooling loop with lines A through D identifying refrigerant states.
Refrigeration cycle state-and-flow tracing · Open full-size diagram in a new tab
Diagram text description

Four-component cooling loop with lines A through D identifying refrigerant states. Refrigeration cycle state-and-flow tracing Refrigerant circuit • Dimensions and states shown govern this exercise • Not to scale Compressor Outdoor coil Metering device Indoor coil A B C D Cooling mode • refrigerant direction EXERCISE BASIS Ideal cooling-cycle concept. A: hot high-pressure vapor. B: high-pressure liquid. C: low-pressure mixture. D: low-pressure vapor. Arrows form Compressor → Outdoor coil → Metering device → Indoor coil → Compressor. A labels compressor-to-outdoor, B outdoor-to-metering, C metering-to-indoor, and D indoor-to-compressor.

  1. 11Which labeled line carries refrigerant directly into the compressor?

  2. 12Between which two labeled lines is pressure reduced?

  3. 13Starting just after the metering device, which ordered route returns refrigerant to the compressor before another pass through the outdoor coil?

  4. 14Which labeled line is identified as high-pressure liquid?

  5. 15Following the shown cooling-cycle direction, which component receives line A before refrigerant enters line B?