Free C-36: Plumbing practice test

  • 15 questions
  • ~8 minutes
  • Scored instantly

15 questions from the Peerless Institute C-36: Plumbing exam, including five questions about one diagram. The C-36: Plumbing exam covers the following topics:

  • Planning and Estimating22%
  • Underground and Rough Systems22%
  • Finish Plumbing Installations20%
  • Service, Repair, and Remodel Plumbing Systems19%
  • Safety17%

Percentages are approximate, per the CSLB examination content outline.

Study materials for this exam

0 of 15 answered
  1. 1Excluding exceptions, cleanouts must be installed in horizontal drainage pipe at intervals of not more than 100 feet.

  2. 2Gas water heaters burning not more than 40,000 BTU’s per hr. may be connected with approved metal tubing connectors having a nominal diameter of 3/8” and an overall length not to exceed _____ inches.

  3. 3Code mandates that a vent pipe for a gasfired water heater with a 4 inch diameter draft hood outlet connect with a vent pipe whose diameter is at least ____ inches.

  4. 4Appliance connectors shall not have a diameter less than: appliance. Code Tables 13-1 and 13-2. appliance manufacturer.

  5. 5A miniature boiler is a boiler having an internal shell diameter of 16 inches or less and a gross volume of 5 cu. ft. or less for steam or vapor under pressures exceeding _____ psi and not exceeding _____ psi.

  6. 6Building sewers or drainage piping constructed of materials which are not approved within a building shall not be run or laid in the same trench with water service pipes or any underground water pipes: solid shelf excavated at one side of the common trench. points, shall be at least twelve (12) inches above the top of the sewer line. and approved by the Administrative Authority.

  7. 7All gas piping shall be adequately supported by metal straps or hooks at intervals of not more than 6 feet for piping, one (1) inch and smaller and not more than ______ feet for larger piping.

  8. 8When the water pressure is 60 lbs. per sq. in., the maximum flow rate for a private lavatory shall not exceed:

  9. 9Domestic gas piping shall stand a pressure of not less than ____ lbs. psi, or may be tested at a pressure of at least ____ in. of mercury.

  10. 10A combination waste and vent stack with a diameter of two inches, that does not exceed 30 feet in length, shall not receive the discharge from:

Diagram practice

Use this diagram to answer the next five questions. Use the stated exercise data; the drawing is not to scale.

Two fixture branches entering a common stack at different elevations with a conceptual vent.
DWV isometric fixture-to-stack tracing · Open full-size diagram in a new tab
Diagram text description

Two fixture branches entering a common stack at different elevations with a conceptual vent. DWV isometric fixture-to-stack tracing DWV isometric topology • Dimensions and states shown govern this exercise • Not to scale Lav A Sink B Building drain Vent concept EXERCISE BASIS Topology exercise only; fitting/vent code compliance not established. Lav A upper-left and Sink B lower-left each have a blue branch connecting to a common vertical stack at different elevations. A green vent rises from the upper fixture branch before it reaches the stack. A separate arrow from the lower stack leads down-right to Building drain.

  1. 11Which fixture joins the stack at the lower connection?

  2. 12Which route reaches the building drain from A?

  3. 13Can this simplified drawing establish vent-code compliance?

  4. 14Trace the green conceptual vent to the blue drainage line. Where does it join in this drawing?

  5. 15Which downstream element is common to both illustrated fixture drainage routes?